What's new in Electra Cloud

Jul
27
  • Added Wire Bus symbol
Jul
25
  • You can now import PDF files in dashboard
Jul
22
  • Fixed bug that causes symbol icon too big when editing symbol icon
  • Added option to insert page after the current page
  • Improved the add/edit component dialog to be able to set category on the component
Jul
18
  • Fixed bug that causes the pin set reset to default after editing the symbol reference
Jul
16
  • Added option to add or delete connection point in context menu
  • Fixed bug that cause text alignment icon not updated properly
Jul
10
  • Fixed bug on downloading stencils in Firefox
Jul
9
  • Fixed bug on DXF INSERT entities
Jul
8
  • Fixed bug that causes inability to name a version
  • You can now export drawing to pdf from the dashboard
Jul
7
  • You can now export and import symbols, wires, tubes, and hoses from/to the drawing
Jul
6
  • Updated the Cable dialog to show sorted cable list in the cables dropdown
  • Fixed bug that causes insert wire name not working as expected
Jul
3
  • Bug fixes for import databases from Electra E8.
  • Fixed bug that causes orphan description and pins after creating new schematic symbol and refreshing the drawing
  • DXF ELLIPSE entities import improvements
Jul
2
  • Fixed bug that causes Set PLC dialog not showing the labels correctly
  • Added 0.5px option for line weight
Jul
1
  • DXF ELLIPSE entities import fix
Jun
30
  • Fixed scrolling issue in Firefox
  • Skip DXF paper space that causes duplicate
  • Suffix for terminal list is now available.
Jun
27
  • Support JSON and CSV for importing component, cable, tubing, and hosing databases
  • Improved generation of terminal lists to show the location of the linked terminal
Jun
26
  • Able to import material reference now.
  • Able to import and export component database in TSV format
  • Fixed bug that causes inability to join paths
  • Improved cable dialog and manage wiring dialog to ensure unique cable name when selecting new cable from database
Jun
23
  • Fixed PLC module
  • Added open in new tab button for help dialog.
Jun
22
  • Fixed v:layer_json undefined value
  • Fixed hyperlink null value
  • DXF now supports LEADER entities
  • Fix drawing save failure on a very large drawing
Jun
19
  • Improved exportPDF to be able to export huge drawing
  • Fixed DXF layer import
Jun
16
  • Fixed inability to add new component to particular category
Jun
13
  • Improved layout shapes to be able to be placed and arranged automatically on rails.
Jun
11
  • Fixed bug that causes the line become shorten after setting arrow on begin point
  • Fixed bug that causes inability to change path's arrows
Jun
10
  • Fixed bug that causes inability to connect to connection point after the symbol is dropped
  • Fixed bug that causes connection point in the symbol not positioned correctly after Electra resized it
Jun
9
  • Improved Component Database dialog to automatically scroll to the component when adding or editing component
  • Fixed bug that causes images missing after refresh
Jun
5
  • Fixed bug that causes missing font when exporting to pdf,jpg and png
  • Improved PLC module
Jun
3
  • Fixed bug that causes browser freeze when connecting wire to another wire which is connected with wire link
  • Fixed bug that causes the text not display properly after set the font size
  • Fixed bug that causes error when creating new symbol on an empty stencil
May
30
  • Fixed bug that causes the jump connector not updated properly after connecting to a shape
  • Fixed bug that causes the wires disconnect from wire links after moving them
May
29
  • Fixed bug that causes error when export drawing to PDF
May
27
  • Fixed bug that causes the Auto Location not updated properly after ungrouped a symbol
  • Fixed a few bugs in PLC module generation
May
22
  • Fixed bug that causes inability to right-click on the cable database dialog
May
20
  • Fixed symbols in Electra stencils to display nicely in dark mode
  • Fixed bug that causes wires not being connected properly after Electra straightened them
  • Fixed bug that causes gradient color of imported svg missing after copying and pasting to another page
May
18
  • You can now move the Create Symbol dialog
  • Fixed the dark theme for the symbols in stencil panel
May
16
  • Fixed bug that causes inability to export images
  • Fixed bug that causes connection points of jump connectors not positioned properly when dragging the connector
May
15
  • Fixed bug that causes error when Set PLC
May
14
  • Added document option to enable automatic wiring when dropping symbol
May
13
  • Added Table of Contents symbol to Reports stencil
May
12
  • Improved create schematic symbol feature to preserve pin name position
May
11
  • Fixed bug that causes svg missing after grouped
  • Fixed bug that cases error when creating new symbol with svg shapes
  • Improved create schematic symbol feature to preserve font size of the symbol graphics
  • You can now move the Edit Wire Link dialog
  • Fixed bug that causes the symbol not positioned properly when drag out from a stencil
  • Fixed bug that causes wire names in the Cable Reference Report not generated properly
May
6
  • Fixed bug that causes error when import DXF file
  • Fixed bug that causes inability to create new symbol on a new stencil
May
4
  • Fixed bug that causes the font-size reset to previous font-size
May
1
  • Fixed bug in Firefox that causes the symbol not stick to the cursor when we drag it from the stencil
Apr
30
  • Fixed bug in Firefox that causes inability to delete shape after press enter key in a dialog to close the dialog
Apr
28
  • Added option to always show scroll bar on the stencil in preference dialog
  • Fixed bug that causes terminal become red after the connected wire is copy and pasted on other page
Apr
24
  • Fixed bug that causes the wire name in the Wire Link not updated properly after renamed a wire
Apr
23
  • Added new tutorial videos for Electra Cloud
Apr
22
  • Fixed bug that causes error when export all pages to PDF
Apr
10
  • Fixed bug that causes cable tag not updated properly
  • Fixed bug that causes inability to use existing symbols to create new symbol
Apr
7
  • Fixed bug that causes Cable Tag shows information of wrong cable
Apr
3
  • Fixed bug that causes the inability to set text angle in Shape Properties
  • Fixed bug that causes the saved version not shown in the version history dialog
  • Show message when updating AutoLocation after a symbol is added or its reference is modified
  • Applied transparency on wire link dialog
Apr
2
  • Release wire IEC, hose IEC and tube IEC
  • Added sample drawing for IEC
Mar
30
  • Fixed bug that causes the inability to split wire when a symbol is dropped on top of the wire in page unit other than PX
Mar
27
  • Fixed bug that causes error when drop a symbol to split wire
  • Release cable tag
Mar
25
  • Fixed bug that causes terminal does not split wire properly
  • Added option to set the size of the connector curve
Mar
24
  • Fixed account page to not allow to change payment method if user is not the license owner
  • Fixed bug that causes a symbol that has filter effect become invisible when it is dropped from stencil
  • Fixed bug that causes panel layout does not generated properly
Mar
21
  • Added option to allow Electra Cloud to access contact list for easy sharing of teams and drawings
Mar
18
  • Fixed bug that causes error when export DXF or DWG
Mar
17
  • Fixed bug that causes the inability to create a new drawing from a template
Mar
9
  • Fixed bug that causes cable information missing after split the wire
Mar
6
  • Improved Vecta.Length to accept capital letter units such as MM, CM
  • Fix bug that causes browser freeze when split wire
Mar
5
  • You can now generate and export Connection Report
  • Added option to split wire when dropping a symbol
Mar
4
  • You can now choose the export format (TSV/CSV) in document options
Feb
24
  • Added options to hide certain cable information in Cable Reference Report
Feb
21
  • Fixed bug that causes error when create new drawing from an archived template
  • Fixed bug that causes error when set fill color to a shape
  • Fixed bug that causes account verification failed
Feb
12
  • Fixed bug that causes inability to read shape's layer
  • Fixed bug that causes the connection points not undo properly after the orientation of the symbol is changed
Feb
11
  • Fixed bug that causes the symbol references missing after reverted to an old version
  • Fixed bug that causes the line arrow missing after the shape is flipped
  • Fixed bug that causes the wire not updated properly after the orientation of the symbol
Feb
7
  • Able to insert wire name
  • Fixed bug that causes version history unable to load more history
Feb
5
  • Fixed bug that causes error when edit component
Feb
4
  • Major performance improvements and blocks support for DXF import
  • Fixed bug that causes error when import DXF file
  • You can now import Adobe Illustrator file
Jan
23
  • You can now export DWG file
  • Fixed bug that causes some DXF file failed to import
  • Added option to set keyboard increment in preferences
  • Always show center.x and center.y in shape properties
  • Improved Create Schematic to adjust pin size automatically if the pin name is too long
  • Fixes for share stencil
  • Fixed bug that causes error when accepting invitation from other user
  • Fixed bug that causes error when loading a version history
Jan
21
  • Fixed bug that causes prefab circuit not resize after drop on a page
Jan
16
  • You can now assign cable information to a wire
Jan
13
  • Fixed bug that causes the auto location not updated properly when a symbol is deleted
Jan
10
  • Fixed bug that causes error when copy a title block to another page
  • Fixed bug that causes the wire unable to connect to any of the symbols in Firefox
Jan
6
  • You can now set preference setting for import DXF
  • Fixed bug that causes shared stencil cannot be loaded
Jan
3
  • Added new ladder zone symbol to create ladder diagrams
  • Added new connector symbol that can generate multiple pins for connectors
Dec
28
  • Added ladder steps symbol
Dec
20
  • Added option to disable automatic resizing symbol when dropping a symbol onto page with different measurement unit
Dec
12
  • Fixed DXF Import for LWPOLYLINE entity
Dec
6
  • Updated all the electra symbols
  • Fixed bug that causes text not exported properly when export to DXF
  • Fixed bug that causes pin name not set properly when a symbol is dropped on the drawing
  • You can now split the wire using terminals
Nov
30
  • Fixed bug that causes DXF file not imported properly
Nov
28
  • Fixed bug that causes error when export DXF
Nov
22
  • Fixed bug that causes error when generating Material Reference report
  • Wires now can be connected from end to end
  • Fixed bug that causes error when edit reference on a symbol that does not have description
  • Fixed bug that causes image not display after reload the drawing
Nov
20
  • Optimized the resize operation for wires
  • Fixed bug that causes wire to disconnect after Electra automatically straighten the wire
Nov
19
  • Fixed bug that causes wires not aligned properly when connected to a jump wire
  • Fixed bug that causes the inability of attaching shape to guide
  • Improved DXF importation to handle unicode characters and dimensions
Nov
12
  • Fixed bug that causes the inability to view sample drawing in mobile
  • Fixed bug that causes error when edit profile
Nov
5
  • Fixed bug that causes the jump wire didn't jump after it connected to another wire
  • Fixed bug that causes error when create schematic symbol
  • You can now manage component database, create schematic symbol, create layout symbol, and create title block in demo page without signing in
Oct
29
  • You can now export the drawing as DXF
  • Fixed bug that causes errors when signing up a new account
  • Fixed bug that causes the inability to drag a component to a category in Component Database dialog
  • You can now create your own layout symbols
Oct
24
  • Fixed bug that causes the description on the created schematic symbol not positioned correctly
  • Fixed bug that causes some symbol reference not updated
Oct
23
  • Added versioning control for the drawing
  • Added page prefix for wires and symbols
  • You can now enable or disable automatic propagate wire name from document options dialog
  • You can now enable or disable automatic manage wire dots from document options dialog
  • You can now enable or disable automatic straighten wires from document options dialog
  • Fixed bug that causes wire propagation not working
  • Fixed bug that causes component details not shown in the assign component dialog
Oct
17
  • Fixed bug that causes a problem in email authentication process
  • Fixed bug that causes incorrect sizing when a symbol drop on the page with meter unit
Oct
16
  • Fixed bug that causes error when a symbol with reference name that located by Auto Location is deleted
  • Fixed bug that causes sub group shapes not resize properly
Oct
8
  • You can now double click on the Auto Location symbol to open the Locate Reference dialog easily
  • You can now view different pages of a drawing in View mode
Oct
4
  • Able to replace layout shape when change the layout shape to another for component
  • Now the wires will automatically straighten when you resize its connected wire
  • Fixed bug that causes incorrect width and height after generated layout
  • You can now export Cross Reference Report
Sep
30
  • You can now double click on the Edit Wire Link dialog to set Wire Link
Sep
26
  • Improved the User Interface of the dialogs
  • Fixed bug that causes target name incorrect in Auto Rename dialog
  • Fixed bug that causes pin names not updated when copy multiple shapes
  • Fixed bug that causes error when cut and paste terminal list
  • Fixed bug that causes Select Component dialog unable to get category
  • Able to generate Layout shapes
  • Able to create Prefab Circuits
Aug
28
  • Improved the Export Material Reference Report to be able to export Layout, Layout Shape, Width, and Height
Aug
26
  • Fixed bug that causes the references not sorted when generate Cross Reference Report
Aug
23
  • Sample drawing is updated
  • Now you can generate Cross Reference Report
  • Now you can export and generate Material Reference Report and Bill of Material Report
Aug
2
  • Able to resize symbols to fit on grid when dropping them onto page
  • Fixed bug that causes the selection box not updated when a symbol is drop onto a page
Jul
5
  • Able to double click on wire to show Edit Wire dialog
  • Able to double click on symbol to show Edit Reference dialog
  • Fixed bug that causes the page number title block data not updated after arranging page
  • Fixed bug that causes UI layout misaligned after selecting sorting in component database. Only happens in Safari browser
Electra Cloud